How many main generators are onboard a type 23 ?
4
1 of 13
What is the output of a type 23 generator ?
1.3MW, 600V, 61.2Hz, 3 Phase
2 of 13
List seven breakers found on a type 23 electrical distribution system.
Supply breaker
Interconnecting breaker
Shore supply/Ship supply breaker
Electric motor breaker
Motor Generator feeder breaker
Motor Generator Supply breaker
Diesel Generator alternative supply breaker
3 of 13
What is the purpose of the generator test box and where is it connected ?
It is used to test and trial the generators using different loads and is connected forward and aft of the 600V bus bars.
4 of 13
What is the purpose of the converter regulator ?
It steps up 600V to 750V used for propulsion.
5 of 13
What are the 3 types of EDP and state their characteristics.
Type 1- circuit fed directly off normal, circuit fed directly off alternative, multiple circuits fed off normal/alternative as switched, made up of ACOS/ROCOS
Type 2- multiple circuits fed from Normal/Alternative as switched.
Type 3- Has a single input fe
6 of 13
What is meant by the term shedable ?
Shedable EDP's are used to dump supply to un-necessary equipment and redirect it to propulsion systems in emergency situations.
7 of 13
What is an alternative way we can produce 450V ?
We can reconfigure a 600V generator to 450V using a 4 position switch located on the back of the switchboard.
8 of 13
What is the output of the emergency Generator ?
270Kw, 450V, 60Hz, 3 phase
9 of 13
What does the emergency switchboard supply ?
Steering motors, HPSW pumps, Surgery/sickbay, smoke clearance fans, portable pump sockets.
10 of 13
List 9 components of the electric propulsion motor and its cooling system.
Yoke, Com pole, Main pole, armature, commutator, brush gear.
Air filter, Cooling fan, exhaust trunking.
11 of 13
What does LCP stand for and where is it located ?
The local control panel(LCP) is located in the converter regulator cabinet.
12 of 13
If the heat exchanger on the converter regulator cabinet fails what can be done to cool it ?
2 emergency inlet flaps can be opened allowing air to be drawn directly into the cabinet.
13 of 13

Other cards in this set

Card 2

Front

What is the output of a type 23 generator ?

Back

1.3MW, 600V, 61.2Hz, 3 Phase

Card 3

Front

List seven breakers found on a type 23 electrical distribution system.

Back

Preview of the front of card 3

Card 4

Front

What is the purpose of the generator test box and where is it connected ?

Back

Preview of the front of card 4

Card 5

Front

What is the purpose of the converter regulator ?

Back

Preview of the front of card 5
View more cards

Comments

No comments have yet been made

Similar Engineering resources:

See all Engineering resources »See all Type 23 distribution and propulsion resources »